Know before you buy
-
Single-phase supply
For a single-phase circuit. Ask your electrician to check supply compatibility.
-
Choose the 63A rating
Have your electrician assess the combined connected load against the 63A rating.
-
Device without mount
Protective enclosure is not included in this option. Arrange DIN-rail installation by a qualified electrician.
Features that make it useful
-
Three protection settings
Adjustable over-voltage, under-voltage and overload cut-off settings.
-
Automatic reconnect
Reconnects after the supply recovers and your selected delay has passed.
-
Live LED readings
View voltage and current on the built-in display.
How to use
-
Check supply and load
Ask your electrician to check the circuit and appliance requirements against the 63A rating.
-
Install and set limits
Arrange professional installation and select suitable cut-off settings and reconnect delay.
-
Monitor the readings
View voltage and current on the LED display. Power reconnects automatically after recovery and the selected delay.
Automatic Voltage & Overload Protector
Upgraded Model · Latest Model · 63A · Black · Without mount
Cuts power when voltage moves outside your set range or current exceeds your limit, then reconnects automatically after recovery and the selected delay.
Orders are processed before 2 PM on dispatch days.
Use code
Use code
Use code
Couldn't load pickup availability
Manuals & videos
Specifications
| Country of Origin | India |
|---|---|
| Model | Black model |
| Current rating | 63A |
| Package option | Device without protective mount |
| Supply | Single phase |
| Under-voltage adjustment (P5) | 80–210V; default 170V |
| Power-on delay (P1) | 1–999 seconds, adjustable |
| Recovery delay (P2) | 1–999 seconds, adjustable; default 30 seconds |
| Voltage protection action time (P7) | 0.1–10 seconds, adjustable; default 0.5 seconds |
| Overload adjustment | 1–63A |
| Display | LED voltage and current readings |
| Device mounting | DIN rail |
Frequently asked questions
Which current rating should I choose?
Does this option include a mount?
Can I adjust the protection settings?
How does automatic reconnect work?
Do I need an electrician?
Is the black model available in 80A?
Full Product Description
amiciSmart 63A Automatic Voltage & Overload Protector
The black AS-OVP-63A model monitors a single-phase circuit and disconnects the supply when voltage or current crosses the configured protection limits. It reconnects automatically after recovery and the selected delay.
- 63A black model, without enclosure: This listing supplies the device without a protective mount. Arrange DIN-rail installation by a qualified electrician.
- Adjustable protection: Under-voltage setting P5 covers 80–210V, with a default of 170V. Overload adjustment covers 1–63A. Over-voltage protection is also adjustable.
- Separate delays: Power-on delay P1 and recovery delay P2 each adjust from 1–999 seconds. P2 defaults to 30 seconds.
- Voltage action time: P7 adjusts from 0.1–10 seconds, with a default of 0.5 seconds; response is not fixed at 0.1 seconds for every setup.
- LED display: View voltage and current on the front display.
- Installation: Ask an electrician to check circuit requirements, connected load and suitable settings. The 63A rating alone does not establish suitability for every household circuit.
The black model is currently available in 63A only. The white 80A model is a separate listing.