125A Automatic / Manual Transfer Switch

400V AC · Three-phase · 4-pole

Automatically changes between main and backup power, with manual control when needed. A 125A, 4-pole three-phase changeover switch for a compatible backup-power installation.

Sale price Rs. 4,099.00 -32% Regular price Rs. 6,000.00 (MRP Inclusive of All Taxes)
Regular price Rs. 4,099.00
125A Dual Power Automatic Control Transfer Switch (3-Phase) Auto & Manual Mode
Sale price Rs. 4,099.00 Regular price Rs. 6,000.00 (MRP Inclusive of All Taxes)
Regular price Rs. 4,099.00
Superfast Shipping

Orders are processed before 2 PM on dispatch days.

5% OFF on all orders

Use code

10% OFF on new launch

Use code

10% OFF on purchase of ₹5000+

Use code

Manuals & videos

Specifications

Brand amiciSmart
Model marking AMATS2-125/4P
Rated current 125A
System Three-phase AC
Poles 4P
Rated voltage 400V AC (nameplate rating)
Frequency 50/60 Hz
Operation Automatic and manual
Mounting DIN-rail mounting
Approx. dimensions (W × D × H) 14 × 6 × 9.5 cm
Approx. weight 740 g
Listed switching time Under 8 ms (listed)
Rated insulation voltage 690V AC
Impulse withstand voltage 8kV
Contact material Silver alloy (as listed)

Frequently asked questions

Does it switch automatically, and is manual operation available?
Yes. This is an automatic/manual transfer switch. AUTO provides automatic changeover to an available backup supply; MANUAL gives operator control. Follow the unit instructions for changing modes and do not force the handle while it is in AUTO.
Is this the single-phase or three-phase version?
This is the three-phase, 4-pole version, rated 125A. Other transfer-switch listings in this family have different pole counts, current ratings and operating modes; check all three before ordering.
Can I connect a generator or inverter as the backup source?
A compatible AC backup supply can be used as part of a correctly designed three-phase installation. Ask your electrician to verify its voltage, frequency, output capacity and wiring arrangement. The switch selects a source; it does not generate or store backup power.
Will the transfer be completely uninterrupted?
The published switching-time figure is under 8 ms. This does not guarantee that every appliance or sensitive device will continue without a reset. Backup power must already be available; equipment requiring uninterrupted power needs a suitable backup design.
Will it fit my distribution board?
The listed approximate size is 14 × 6 × 9.5 cm (width × depth × height), with din-rail mounting. Allow space for terminals, wiring and safe operation; have your electrician check the enclosure before purchase.
Can I choose it from the current rating alone?
No. The 125A rating is one part of selection. Confirm phase arrangement, pole count, connected load, starting current, backup-source capacity and the installation requirements. Do not assume the full home or business load is suitable just from the product name.

Full Product Description

125A Automatic / Manual Transfer Switch — Three-phase, 4P

The amiciSmart 125A dual power automatic/manual transfer switch is designed to select between main and backup AC supplies in a three-phase installation. It is a four-pole changeover device for homes, shops, workshops or commercial panels where its ratings and installation requirements match the application.

Automatic changeover with manual control

Automatic mode transfers to an available backup source when mains power fails. Manual mode provides operator control when needed. Follow the product instructions for mode changes and manual operation; do not operate the handle forcibly while AUTO is selected.

  • Rated current: 125A.
  • Three-phase AC; 4P configuration.
  • Rated voltage: 400V AC (nameplate rating); frequency: 50/60Hz.
  • DIN-rail mounting; approximate dimensions: 14 × 6 × 9.5 cm (W × D × H). Approximate weight: 740 g.
  • Published switching time: Under 8 ms (listed). This figure does not guarantee uninterrupted operation for every connected device.
  • The existing product specification lists silver-alloy contacts, 690V AC insulation voltage and 8kV impulse withstand voltage.

Choose a compatible power setup

The backup source must be available and correctly sized for the connected load. A generator or inverter installation needs compatible AC voltage, frequency, phase arrangement and wiring. This transfer switch does not produce electricity, store energy or convert three-phase power to single-phase power.

Installation and operation

Have a qualified electrician confirm load suitability, enclosure space and the required wiring and protection. Product dimensions are approximate and do not include all installation clearances. Use the markings and instructions supplied with the actual unit. A switching or OFF position must not be treated as proof that incoming terminals are safe to touch.

Choose the right model

This listing is for the 125A three-phase automatic/manual model. Other family members differ in operation, number of poles and current rating. Compare these details before choosing.

Support

Contact amiciKart for product and installation-document queries. Current warranty, delivery, returns and payment information is shown by the store's policy and checkout sections.

You may also like