Know before you buy
-
Electrician required — not DIY
Have a licensed electrician plan it, install it on the DIN rail and commission it — especially on 63A circuits.
-
Single-phase ~230V · up to 63A + upstream MCB
For single-phase two-wire use, rated 63A. It must be combined with an MCB for short-circuit protection and does not replace required breakers.
-
Mount option is separate
Without Mount (1xTOMZN-DDS238-VAP) vs With Mount (1xTOMZN-DDS238-VAP-M). Pick the accessory you need.
Features that make it useful
-
Adjustable OV / UV / OC protection
Over-voltage 120–300V, under-voltage 85–300V and overload 1–63A. Factory defaults: over-voltage 270V, under-voltage 170V, over-current 40A.
-
Auto reconnect
Reconnects automatically after the supply recovers, with an adjustable delay — check the delay range in your unit's settings menu.
-
LCD energy + live electricals
Shows active energy (kWh), voltage, current and power, with bi-directional total active energy metering.
-
DIN-rail compact body
About 35×81×60 mm and fits a 35 mm DIN rail.
How to use
-
Plan circuit with a licensed electrician + MCB
With your electrician, check the single-phase supply, 63A suitability, cable capacity and the upstream MCB.
-
Install on DIN rail and set limits
Electrician wires L/N in and out per the device diagram (neutral must be correct). Set OV / UV / OC and reconnect behaviour for your site.
-
Check readings and trip behaviour
Check the LCD V/A/W/kWh readings, then test the protective trips and auto-reconnect under supervised conditions.
63A Digital Energy Meter + Voltage/Overload Protector
230V single-phase · Over/under voltage · Over-current · Auto reconnect · LCD · Optional mount
DIN-rail single-phase meter/protector with LCD V / A / W / kWh, adjustable over-voltage, under-voltage and overload cut-offs, and auto-reconnect. With or without mount. Install by a qualified electrician with an upstream MCB.
Orders are processed before 2 PM on dispatch days.
Use code
Use code
Use code
Couldn't load pickup availability
Manuals & videos
Specifications
| SKU — Without Mount | 1xTOMZN-DDS238-VAP |
|---|---|
| SKU — With Mount | 1xTOMZN-DDS238-VAP-M |
| Installation | By a qualified electrician, with an upstream MCB |
| Device type | DDS238-VAP multi-function protector / energy monitor |
| Supply | Single-phase two-wire AC; 230V / 63A |
| Working voltage | 85–300V |
| Over-voltage range | 120–300V adjustable (default 270V) |
| Under-voltage range | 85–300V adjustable (default 170V) |
| Over-current range | 1–63A adjustable (default 40A) |
| Reconnect / switch-on delay | Adjustable — see the unit's settings menu |
| Fault response | 0.1 s fault response |
| Metering | Bi-directional total active energy; display to 9999.9 kWh class |
| Accuracy | ±0.5% V/A/W; ±1% active energy (IEC62053-21) |
| Mounting / size | 35 mm DIN rail; ~35×81×60 mm |
| Frequency | 50/60 Hz |
| Warranty | 1 year (12 months from sale) |
Frequently asked questions
Do I need the With Mount option?
Can this replace my MCB?
What are the factory defaults?
Is installation DIY / no electrician?
Does it meter solar export?
Full Product Description
DDS238-VAP Digital Energy Meter & Voltage/Overload Protector (63A)
Available Without Mount (1xTOMZN-DDS238-VAP) or With Mount (1xTOMZN-DDS238-VAP-M).
Installation
Install by a qualified electrician with an upstream MCB. This protector must be combined with a miniature circuit breaker for short-circuit protection.
Protection & metering
- Adjustable over-voltage, under-voltage and over-current protection with LCD V / A / W / kWh.
- Automatic or manual reclosing after the supply recovers.
- Malignant-load / pure-resistive limit features and fault-reason logs.
Support
1-year (12-month) warranty, supported by amiciKart.