Specifications:
Supply Voltage: AC110-220V
Relay output contact : 2200W
Temperature Range: -20°C ~ +80°C
Measuring humidity range: 00%RH~+100%RH
Accuracy: ±1°C 0.1%RH
Size:75mm*85mm*35mm
Temperature Setting:
Heating and Cooling Mode Setting:-
Press and hold first ▲ button for 3 seconds to start temperature (20°C default). Press and hold first ▼button 3 seconds to stop temperature (30°C default), Use▲▼button to set Stop Temperature value.
Humidity Setting:-
Press and hold other ▲ button for 3 seconds to start humidity (40%RH default). Press and hold first ▼button 3 seconds to stop humidity (60%RH default), Use▲▼button to set Stop humidity value.